Parveen Garg, an engineering graduate from Regional Engineering College aka NIT Kurukshetra has joined us in year 2000 as a fresher.  He has worked with a variety of assignments and activities since his association with the company and today possess the “Business and Technical” Acumen that aligns with the vision of the company. He himself being stepped up from the fresher, grown with the company’s growth,  has flair towards having “Fresh Engineering Graduates” in our team and grooming them up.  He is always accessible for any business/ Technical  need, idea, support or a new concept.

Power supply for voice communication & control system system

SMM-A10060

Input Voltage220 VAC (150V-264V)
Outputs-48VDC@1.2A
Line & Load Regulation±1% Low line to High Line
Ripple<50mVp-p
EfficiencyBetter then 80%
Operating Temperature-40℃ to 75℃
CoolingNatural convection Cooled Inbuilt
ProtectionsShort Circuit, output over load, I/O Isolation, Over Temperature & Under/ Over Voltage
Dimensions56mm(W) x 43mm(H) x 160mm(D)
Weight<1Kg
I/O Connector D-Type connector
  • EMI/EMC Compliances to MIL-STD-461E
  • Environmental As per JSS/55555

Power Supply for Naval communication system

SMM-A201400

Input Voltage380V AC(L~L),Three Wire/415 AC(L~L),Four Wire
Output Voltage & output current28V/50A, 65V /10A
Output Ripple & Noise150 mVp-p
Efficiency>80%
Operating Temperature-55°C to +85°C
CoolingNatural Cooling
ProtectionsOver Voltage, Over Current, Over Temperature, IP protected, Short Circuit
Dimensions200mm (L) x 140mm (W) x 90mm (H)
Weight~2.5kg
I/O ConnectorsInput / Output Circular Connectors
  • EMI/EMC Compliance, Fully Rugged Design and Input and Output isolated.

24V DC UPS for Ship Borne (IPMS)

SMM-AD101500

Input Voltage415VAC, 3Ø, ±10%
Outputs Power1,500Watts
Output Ripple & Noise< 150mV p-p @ 20MHz
Efficiency>80%
Operating Temperature0°C to +55°C
CoolingForced Air Cooling
Protectionsover voltage protection ,short circuit protection, Transient Voltage Surges, Load and Supply Fluctuations
Dimensions850mm (H) x 500mm (W) x 300mm (D)
WeightLess than 245 Kg
I/O ConnectorsCircular Connectors
  • EMI/EMC Compliance to Mil Std- 461E, Fully Rugged Design as per Environmental Specs as per JSS-55555