Test Equipments

EMC Analyzer9kHz-1.5GHz
LISN10A
Bi Conical Antenna30MHz-300MHz
Log Periodic Antenna200MHz-2GHz
Closed Field Probe-I9KHz-30MHz
Closed Field Probe-II30MHz-1GHz
Oscilloscope (Mega Zoom)100MHz, 200MS/s, 4 Channels
Data Acquisition Switch61/2 Digit, 22 Channels
400Hz Source230V/1Phase/400Hz/5KVA
400Hz Source115V/3Phase/400Hz/10KVA
Processing UnitPIV PC + Network GPIB
Digitally Controlled Oven

Power Supply For Electrical Drive System

SMM-A13500

Input415VAC, 3-Phase, 50Hz
OutputsElectrical drives for driving 4 sets of type 1 clutch coils, Electrical drives for driving 4 Nos type 1 motors, Electrical drives for driving 4 Nos P type motors, Electrical drives for driving 1 No. C type motors
Efficiency>80%
Operating Temperature0℃ to 40℃
CoolingForced Air Cooling
ProtectionsOverload Protection, Short Circuit Protection
DimensionStandard 19″ Rack Mountable, 28U Height
Weight100.0Kgs
I/O ConnectorsInput Output Circular Connector
  • EMI/EMC Compliance as per cisper 11, Environmental as per Seismic test

Power Supply For Radiation Detection Electronics

RID Concentrator

Input220VAC, 3-Phase, 400Hz, Line to Line
Outputs2 No’s of 5VDC@5A
Line & Load RegulationLine Reg:<0.5%, Load Reg:<5%
Output Ripple & Noise<50mv
Efficiency>70%
Operating Temperature5℃ to 45℃
CoolingConducting Cooling
ProtectionsShort Circuit Protection
Dimension112 x 350 x 210mm
Weight10.0Kgs
I/O Connectors30 Pin Connector
  • EMI/EMC Compliance To MIL-STD-461E, Environmental Compliance to JSS-55555

90V Cluch Power Supply

SMM-D10720

Input220VDC
Outputs5VDC, 8A
Line & Load Regulation1%
Output Ripple & Noise200mv
Efficiency>80%
Operating Temperature0℃ to 70℃
CoolingForced Air Cooling
ProtectionsOverload Protection, Short Circuit Protection
DimensionStandard 19″ Rack Mountable, 4U
Weight10.0Kgs
I/O ConnectorsInput Output Circular Connector
  • EMI/EMC Compliance as per cisper 11, Environmental as per Seismic test

Power Supply For PLC SCADA

SMM-D10081

Input24VDC
Outputs5VDC, 8A
Line & Load Regulation1%
Output Ripple & Noise50mv
Efficiency>75%
Operating Temperature0℃ to 70℃
CoolingNatural Cooling
ProtectionsOverload Protection, Short Circuit Protection
Dimension6U & Width 28mm
Weight1.0Kgs
I/O Connectors100 Pin I/O Connector
  • EMI/EMC Compliance as per cisper 11, Environmental as per Seismic test

Power Supply For PLC Control

SMM-A10125

Input195-265VAC, Single Phase, 45-55Hz
Outputs5VDC, 25A
Line & Load Regulation1%
Output Ripple & Noise50mv
Efficiency>75%
Operating Temperature0℃ to 70℃
CoolingForced Air Cooling
ProtectionsOverload Protection, Short Circuit Protection
DimensionStandard 19″ Rack Mountable, 1U
Weight3.0Kgs
I/O ConnectorsInput 3 Pin IEC Connector & Output Terminal Block
  • EMI/EMC Compliance as per cisper 11, Environmental as per Seismic test

Power Supply For PLC SCADA

SMM-A10080

Input180-265VAC, Single Phase, 45-55Hz
Outputs15VDC, 16A
Line & Load Regulation1%
Output Ripple & Noise50mv
Efficiency>75%
Operating Temperature0℃ to 70℃
CoolingNatural Cooling
ProtectionsOverload Protection, Short Circuit Protection
Dimension6U & Width 28mm
Weight1.0Kgs
I/O Connectors100 Pin I/O Connector
  • EMI/EMC Compliance as per cisper 11, Environmental as per Seismic test

Power Supply for Electrical drive system

SMM-A13500

Input Voltage415VAC 3-Phase, 50Hz
OutputsElectrical drive for driving 4 set of type 1 clutch coils, Electrical drive for driving 4 Nos. type 1 motors, Electrical drive for driving 4 Nos. P type motors, Electrical drive for driving 1 Nos. C type motors
Output Ripple & Noise<50mv
Efficiency>80%
Operating Temperature0℃ to 40℃
CoolingForced Air Cooling
ProtectionsO/P over voltage protection ,short circuit protection
DimensionsStandard 19” rack mountable, 28U height
Weight100.0Kgs
I/O ConnectorsInput / Output Circular Connectors